Experimental study on axial compressive behavior of composite column specimens with openings on steel tube wall

Wan Yixiu,Li Ningbo,Wu Zhaohua,Liu Xiang,Zheng Tongliang,Qian Jiaru
DOI: https://doi.org/10.19701/j.jzjg.2013.11.003
2013-01-01
Abstract:To study the influence of opening ratio of the steel tube wall on the axial compressive behavior of core area of RC beam and concrete filled steel tube composite column joint,quasi-static tests on 18 composite column specimens were conducted.Among the 18 specimens,there were 14 specimens with large openings and 4 specimens without openings on the steel tube wall.Results indicate that the openings have little influence on the axial compressive strength of the specimens when the opening ratio is less than 50%.For the specimens with the opening ratio of 50%,the axial compressive strength increases significantly when the thickness of steel tube wall increases from 8mm to 12mm or 14mm.The axial compressive load-longitudinal strain curves of the specimens drop slowly and the plastic deformation capacity enhances greatly,when the steel tube is strengthened by stiffeners along the perimeter of openings.Taking into consideration of the confinement effect of steel tube on the core concrete,the calculated axial compressive strength of specimens is in good agreement with the test results,but it is much smaller than that of the test results without taking into consideration of the confinement effect of steel tube on the core concrete.Taking into consideration of the confinement effect of steel tube on the core concrete is recommended in the calculation of axial compressive strength of specimens.
What problem does this paper attempt to address?