An Experiment Study of Axial Compressive Strength of Concrete Filled Steel Tube Composite Columns

Kang Hongzhen,Qian Jiaru
2006-01-01
Abstract:The concrete filled steel tube (CFST) composite column is a newly developed structural element for earthquake resistant buildings.A composite column is a reinforced concrete column with a CFST at its center.In order to establish the axial compressive strength formula for CFST composite columns,axial compressive loading tests of 18 specimens have been carried out.Test parameters were the diameter and thickness of steel tube,the cubic strength of concrete outer of steel tube and the stirrup characteristic value.The failure process,compressive force-strain relationship curves of specimens were obtained.The test results show that the axial compressive strength of the CFST composite column is the sum of that of CFST and that of the reinforced concrete out of steel tube.A formula for calculating the axial compressive strength of the CFST composite columns is proposed.The test results also show that the axial compressive strength of CFST can be taken as the remaining strength of the CFST composite columns.
What problem does this paper attempt to address?