Solid phase microextraction coupled with GC/MS for the determination of benzene series in indoor air

HU Yu-ling
2010-01-01
Abstract:A homemade portable dynamic air sampling device of solid phase microextraction(SPME) was designed and applied to the determination of benzene,toluene,ethyl benzene,p-xylene and 1,3,5-trimethylbenzene in indoor air coupling with GC/MS.The linear range of the SPME-GC/MS method was from 1 to 300 μg/m3.The detection limits were 0.1~0.3 μg/m3 and RSDs(n=6) were 3.2%~15%.The average concentrations of benzene,toluene,ethylbenzene,p-xylene and 1,3,5-trime-thylbenzene in indoor air of 20 new decorated houses were 17.59,30.86,12.63, 22.12 and 55.32 μg/m3 respectively.The results of alkyl benzenes in new decorated houses indicated that kitchens were the most seriously polluted areas due to oil smoke and waste gas.