Ventilation experiments of 700 MW class turbine generator

ZHANG Jia-kang,ZHENG Dong-ping,DENG Qi-lin
DOI: https://doi.org/10.3969/j.issn.1008-8857.2012.01.006
2012-01-01
Abstract:In this paper,the ventilation and cooling system of a 700 MW class turbine generator was described in detail,and the design features of the system were summarized.During site test of the generator,ventilation experiments were carried out.Pitot tubes were used to measure the pressures in frond of and behind the fan and the cooler,as well as in each inlet and outlet zones.The total flows and the static-pressure distributions in every zones of the generator were obtained.A comparative analysis showed the experimental results are in fairly good agreement with the design values,and the ventilation and cooling system can meet the requirements of long-time and safe operation of the turbo generator.
What problem does this paper attempt to address?