Research on Influence of Service Conditions on Water Consumption of Wet Desulphurization System

ZHANG Fang-wei,WANG Zi-kuan,LI ying-wei,TAN Hou-zhang,XU Chao
DOI: https://doi.org/10.3969/j.issn.1671-9913.2011.06.010
2011-01-01
Abstract:the influence of inlet flue gas temperature,inlet vapor concentration,and liquid-gas ratio on water use in Wet FGD was studied by simulating the practical Wet FGD system in power plant and is evaluated by water level change of water box.Results show that water consumption is 30%~40% less at inlet flue gas temperature 90℃ than that at inlet flue gas temperature 120℃~140℃.The more total moisture in coal,The higher inlet vapor concentration of flue gas and less water consumption.Moreover,when inlet vapor concentration of flue gas is high than 16%,The FGD may not need to add water but to drain.
What problem does this paper attempt to address?