Shaking table test of an ancient timber structure strengthened with CFRP

Xue Jianyang,Zhang Fengliang,Zhao Hongtie,Xie Qifang
2012-01-01
Abstract:A shaking table test of a model of an ancient timber structure,constructed according to the Fabrication Methods of Song dynasty and strengthened with CFRP,was conducted.Quantitative analyses were performed for the displacement and acceleration response of the root,the head of column,Shop Aung,Ru Fu,the earthquake shear of structure and the internal force tenon-mortise node,failure pattern,dynamic property,and torsional effect.The study showed that the friction-sliding of pedestal,rotation of semi-rigid tenon-mortise node and sliding of Shop Aung greatly decreased the dynamic response of the structure,and met the design requirements of no damage under frequent earthquakes,repairable under moderate earthquakes and no collapse under rare earthquakes.Maximal shear force of the structure distributed along the height appeared in the column frame layer or the pedestal,and the maximal bending moment of tenon-mortise node under different conditions was also obtained.Due to the participation of high vibration model and non-uniform distribution of mass and stiffness,there was obvious twist beyond 400Gal.