Hysteresis behavior of traditional timber structures by full-scale tests

Jinyong Chen,Yohchia Frank Chen,Xiwang Shi,Yanxia Zhao,Tieying Li
DOI: https://doi.org/10.1177/1369433217717117
2017-07-10
Advances in Structural Engineering
Abstract:To study the seismic response of a traditional timber structure in China, a full-scale model capturing the main characteristics of a representative ancient Chinese wooden structure in Song Dynasty (960–1279 AD) was established and tested considering three different levels of vertical loads, which is one-story sophisticated timber structure consisting of four columns and Dou-gong sets. A swing column was used to apply the synchronous horizontal force. Tests under the low-cyclic loading were performed considering three levels of vertical load to reveal the hysteretic behavior of the historic buildings. Based on the observed characteristics from restoring forces, the ancient wooden structure appears to have a good ductility despite of its low inherent energy dissipation capability. Based on the test results, the following relationships are established: loads versus displacements with key turning points, the loads at the key points versus the roof weights, the displacements at the key points with the column diameter, and structural stiffness versus ductility. Finally, a limiting value of drift angle for structural design and the equivalent viscous damping and ductility factor for dynamical response analysis are proposed.
construction & building technology,engineering, civil
What problem does this paper attempt to address?