A Monitoring Technique for Wet H2S Corrosion in Propane Tank

OUYANG Yue-jun,YU Gang,WU Yun-dong,HAN En-hou,WU Han-ping,HUANG Wei-guo
DOI: https://doi.org/10.3321/j.issn:1000-2472.2007.01.014
2007-01-01
Abstract:The corrosion monitoring system was composed of a hydrogen sensor with Pd_(75)Ag_(25) alloy film,a model CP5 potentiostat and a computer.The hydrogen sensor signal was steady and reliable.The equations between 16MnR steel corrosion rate and steady current density of hydrogen permeation were used to calculate the wet H_2S corrosion rate of the interior of the equipment by detecting the hydrogen permeation.The in-situ test showed that the monitoring system could be used to monitor the wet H_2S corrosion rate of propane tank and to evaluate the safety state of the equipment operation.