Effect of Parasitic Parameters on Current Distortion of Boost PFC Circuit

XIONG Fei,ZHANG Jun-ming,QIAN Zhao-ming
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2010.21.008
2010-01-01
Abstract:Single phase active power-factor correction (APFC) technology has been widely adopted in low to medium power application. The performance of the APFC converter is heavily related to its control scheme,operation mode and parameters design. Systematic analysis of the circuit parasitic parameters effect on line current total harmonic distortion (THD) in different conduction modes was presented. Due to the traditional analytical method based on the average inductor current model suffers from inaccurate and single parameter analysis,a theoretical analysis model was presented based on the inductor switching current in discontinuous conduction mode (DCM). The effect of main circuit parasitic parameters suth as parasitic capacitor and circuit loss,on the line current THD were analyzed. The effectiveness of the mathematic model and the validity of the theory analysis are verified by the experimental results.