Experimental Investigation on a Flat Heat Pipe Radiator for Cooling High Power LEDs

KOU Zhi-hai,BAI Min-li,YANG Hong-wu
DOI: https://doi.org/10.16136/j.joel.2010.04.012
2010-01-01
Abstract:A novel flat heat pipe radiator is put forward and the experimental investigation on heat transfer performance of the flat heat pipe radiator for cooling high power LED array is established.The startup performance,temperature uniformity of the flat heat pipe radiator and the effects of the heat load and tilt angle on the thermal characteristics in natural convection are analyzed.An electrical-thermal conversion method is used to measure the junction temperature of the high power LED.It is found that the total thermal resistance of the flat heat pipe radiator varies in the range of 0.305 3 ℃/W-0.342 5 ℃/W and it has a reasonable and uniform temperature distribution.The junction temperature of the LED array varies in the range of 47.9 ℃-59.0 ℃ and is far lower than 110 ℃.
What problem does this paper attempt to address?