Study on Treatment of Nylon-6 Wastewater by Using Hydrolysis Acidification/Two-stage Bio-contact Oxidation Process

Fang LIU,Guo-hua LIU,Man ZHANG,Wei SHU,Ji-hua CHEN
DOI: https://doi.org/10.3321/j.issn:1000-4602.2007.05.027
2007-01-01
Abstract:Aiming at the characteristic of good biodegradability of nylon-6 wastewater,the hydrolysis acidification/two-stage bio-contact oxidation process was adopted.The effect of recycle ratio of nitrified liquor,HRT and DO on the treatment efficiency was investigated.The results show that when the recycle ratio of nitrified liquor is 3,HRT is 12.1 h,and DO concentrations of hydrolysis acidification reactor,No.1 and 2 contact oxidation reactors are 0.5 to 1.0 mg/L,3.0 to 3.5 mg/L and 1.8 to 2.3 mg/L respectively,the treatment effect of the system is the best,and the removal rates of COD and TN are 95.85% and 61.04%.The effluent quality reaches the classⅠof the Integrated Wastewater Discharge Standard(GB 8978-1996).