The Temperature and Time-Sharing Running Control Strategy of Two-Circuit Cycle Refrigerator/Freezer with Parallel Evaporators: Ⅰ. Theoretical Analysis

LU Zhi-li,DING Guo-liang
DOI: https://doi.org/10.3321/j.issn:1006-2467.2006.02.020
2006-01-01
Abstract:The existing control strategies of the fresh food compartment(FFC)/freezer compartment(FZC) prior based on the temperature control of the two-circuit cycle refrigerator-freezers(RFs) with parallel evaporators were analyzed.A new control strategy was put forward and analyzed theoretically.Since the maximum running time of FFC cycle and FZC cycle is set,the maximum waiting time of either compartment when it need cooling would be the setting maximum running time of the next cycle,so the long waiting time of either compartment is avoided effectively,and the compartment temperature fluctuation is controlled in the rational range.
What problem does this paper attempt to address?