Achieved Lenticule Diameter and Functional Optical Zone in Hyperopic Eyes after Lenticule Intrastromal Keratoplasty.

Shengtao Liu,Yu Zhao,Jing Zhao,Xiaoxue Zhang,Meiyan Li,Xingtao Zhou
DOI: https://doi.org/10.3928/1081597x-20221107-02
2022-01-01
Journal of Refractive Surgery
Abstract:PURPOSE: To investigate achieved lenticule diameter (ALD) and functional optical zone (FOZ) following femtosecond laser-assisted lenticule intrastromal keratoplasty (FS-LIKE) or small incision lenticule intrastromal keratoplasty (SMI-LIKE). METHODS:Small incision lenticule extraction (SMILE)-derived human lenticules were placed on the surface of a contact glass (CG) and model eye (ME). Ex vivo ALDs were assessed at different hydration times. The ALD and FOZ were obtained us-ing optical coherence tomography and Scheimpflug tomogra-phy at 6 months after lenticule implantation. RESULTS: At 1 hour after hydration, lenticules achieved a slightly larger CG-loading ALD (6.63 +/- 0.07 mm) and similar ME-loading ALD (6.53 +/- 0.07 mm) as compared to a pro-grammed optical zone (POZ) of 6.5 mm (P < .001). At 6 months after surgery, FS-LIKE with a POZ of 6.5 mm obtained an ALD of 6.20 +/- 0.21 mm, which was larger than SMI-LIKE with a POZ of 6.64 mm (5.90 +/- 0.14 mm, P= .001). The mean FOZ di-ameters were 5.33 +/- 0.28 and 5.11 +/- 0.14 mm for the FS-LIKE and SMI-LIKE groups, respectively (P= .022). The absence of significant differences in the ALD and FOZ among the differ-ent meridians indicated that the achieved lenticule and opti-cal zone shapes were circular. CONCLUSIONS: An accurate lenticular size could be obtained from SMILE, and FS-LIKE could achieve a larger FOZ than SMI-LIKE, attributed to attaining a larger ALD.