Treatment of Manganese-containing Wastewater Using Nanofiltration Membrane

Li Meng,Zhu Tong,Zhang Xiangyu,Song Baohua,Wang Zhongyuan,Liu Bo
DOI: https://doi.org/10.3969/j.issn.1006-1878.2012.03.014
2012-01-01
Abstract:The Mn2+-containing wastewater in electrolytic manganese production was treated using nanofiltration membrane.The factors affecting membrane flux and metal ion retention rates were studied.The experimental results show that:The greater the operating pressure is,the greater the membrane flux is,and the faster the membrane flux decreases with the extending of running time;When the operating pressure is 2.0 MPa,the retention rates of Mg2+,Mn2+ and Ca2+ can reach 90.69%,89.72% and 100% respectively;With the addition of scale inhibitor,the membrane flux is slightly larger;After 4 times of backwashing,the membrane flux can be renewed completely.
What problem does this paper attempt to address?