Abstract:The wastewater containing chromium ions was treated at room temperature by NF-1812 nanofiltration membrane.The influences of the operating pressure,mass concentration of chromium ions on the effect of Cr(Ⅲ),Cr(Ⅵ) removal with nanofiltration membrane were investigated,and the separation effect is affected by the morphology,operating pressure,mass concentration of chromium ions.The results show that when the operating pressure is 0.25-0.55 MPa,with the increase of the operating pressure,the membrane flux increases,and the wastewater treatment capacity increases,while the rejection decreases.The removal rate of trivalent chromium Cr(Ⅲ) declines from 93% to 89% and the removal rate of hexavalent chromium Cr(Ⅵ) declines from 37% to 31%.NF-1812 nanofiltration membrane has greater removal rate of Cr(Ⅲ) than that of Cr(Ⅵ).Among the mass concentration of chromium ions of 0.05-0.20 g/L,the rejection of chromium ions decreases with the increase of the mass concentration.The mass concentration of hexavalent chromium Cr(Ⅵ) has less effect on the rejection.NF-1812 nanofiltration membrane can treat the wastewater containing trivalent chromium effectively.