Determination of ciprofloxacin hydrochloride in the human plasma by HPLC

Liu Xing-qi,Deng Fu-liang,Chen Ben-mei,Rao Junming,Zhou Ping
DOI: https://doi.org/10.3969/j.issn.1672-2981.2006.04.013
2006-01-01
Abstract:OBJECTIVE To determine ciprofloxacin hydrochloride in the human plasma by reversed phase high performance liquid chromatography.METHODS Ciprofloxacin hydrochloride was successfully separated using a Diamonsil C_(18) column(200 mm×4.6 mm,5 μm).The mobile phase consisted of acetonitrile-20 mmol·L~(-1) dibasicpotassium phosphate and monobasicpotassium phosphate buffer solution(25∶75)(adjusted to pH 2.83 using phosphoric acid)and was degassed ultrasonically before use.Each component of the mobile phase was filtered through a 0.45 μm membrane.The column temperature was 35 ℃ and the flow rate was 1.0 mL·min~(-1).Injection volume was 20 μL.The peak of ciprofloxacin hydrochloride was monitored with fluorescence detector(290/440 nm).RESULTS The detection limit was 5 ng·mL~(-1).The linear range was 10~4 000 ng·mL~(-1).The average(recovery) was 99.11%~103.80%.RSD of intra-day and inter-day was less than 2% and 5%,respectively.CONCLUSIONS The method is simple,rapid,sensitive and producible.