Experimental study on seismic performance of reinforced concrete short columns after fire

XU Yuye,YANG Qingwen,WU Bo,XU Ming
DOI: https://doi.org/10.14006/j.jzjgxb.2013.08.003
2013-01-01
Abstract:Based on the quasi-static tests of seven reinforced concrete(RC) short columns after fire and one contrastive specimen at ambient temperature,the effects of fire exposure time,axial load ratio and shear span ratio on the failure mode,shear strength,skeleton curve,stiffness degradation,ductility ratio and hysteretic energy were analyzed.The average reduction coefficient of compressive strength in concrete sections was calculated by a finite element program,and a practical calculation method for the shear strength of RC columns after exposure to fire on all sides was proposed.The results show that: the shear strength of short columns decreases with the increase of fire exposure time and shear span ratio.The difference of influence degree of shear span ratio on the shear strength of columns before and after fire is small.With an increase of axial load ratio,the shear strength of short column after fire firstly is increased and then decreasing.The critical value of the influence of axial load ratio on the shear strength of columns after fire is less than that at ambient temperature.The proposed formula for the residual shear capacity of RC columns after fire has certain safety margin ratio,and can be used to assess the shear performance of that member after fire.
What problem does this paper attempt to address?