Effect assessment and defect analysis of coal-mill-house noise control in the thermal power plant

YAO Hong-wei,LIU Kai,SUN Kai,YANG Dong-ling,SUN Xiao-ming
DOI: https://doi.org/10.19937/j.issn.1671-4199.2012.04.009
2012-01-01
Abstract:Objective To evaluate the effect of coal-mill-house noise control in the thermal power plant,and find out the cause of the defects.Methods Field occupational health investigation and noise measurement were carried out for analysis and comprehensive assessment.Results The average sound pressure level in the workshop was reduced from 100.9 dB(A) to 96.8 dB(A) after noise control.The noise reduction level of the best sound insulation cover was between 17.5 dB(A)and 19.4 dB(A),and the average noise reduction level was 18.45 dB(A).The final test indicated that the effect of coal-mill-house noise control was bad.The results of field investigation showed that cylinder bodies were the main sound sources,electric machines were the secondary sound sources in the workshop,and there were no other engineering noise control procedures for reducing the exiting noise level except that the part sound insulation covers were selected to control the cylinder bodies of 12 coal mills and the electric machines of one coal mill.Conclusion The workshop noise level can't be reduced to ideal level because of the defects of the coal-mill-house noise control plan.