Evaluation of Control Effect on Occupational Hazards in a Construction Project of Intelligent Ammeter Factory

Ji-dong SUN,Kai LIU,Shan-shan CHANG,Wei-tao ZHANG,Fu-jun LI
DOI: https://doi.org/10.13329/j.cnki.zyyjk.2011.20.012
2011-01-01
Abstract:[Objective]To prevent,control and eliminate the occupational hazards in a construction project of intelligent ammeter factory,protect workers' health. [Methods]The results of field occupational hygienic investigation,detection and occupational health surveillance of this project were analyzed comprehensively,and the evaluation was conducted according to related laws,regulations,standard and technical specifications. [Results]The main occupational hazard factors in this project were lead fume,tin dioxide,unsteady noise and power frequency electric field.The detection range of time weighted average(TWA) of lead fume was 0.004 mg/m3~0.007 mg/m3,the detection range of tin dioxide TWA was 0.3~0.4 mg/m3,and the detection range of unsteady noise and power frequency electric field was 71.1~80.1 dB(A) and 0.47~1.42 V/m respectively.The occupational physical examination showed that the diseases caused by dust and noise exposure were not detected. [Conclusion]The related occupational protective measures had been carried out in this project.The concentration(strength) of all occupational hazard factors was in accordance with national limit values,which met the requirement of occupational hazard control.