A Method for Improving the Ranging Accuracy of Large Visual Angle 2D Triangulation Range Finder with Dual Lens

WANG Huan-qin,ZHAO Tian-peng,HE De-yong,XU Jun,YIN Zhen-qiang,GUI Hua-qiao,HUANG Wei,MING Hai,XIE Jian-ping
DOI: https://doi.org/10.3969/j.issn.1007-5461.2007.05.019
2007-01-01
Abstract:The experiments for 2D triangulation ranging accuracy show that,under large vi- sual angle condition,the 2D triangulation ranging error is obviously increased.Applying the pinhole imaging instead of normal lens imaging,the large visual angle abaxial light aberra- tion of lens is demonstrated to be the main reason for the ranging error,and an empirical remedy equation is proposed,which can obviously improve ranging accuracy and speed.The experiment results show that,in the 50 mm×50 mm work region corresponding to the visual angle as large as 80°,the average ranging error in x and y direction is better than 2 mm,the average resolutions in x and y direction are 0.2 mm and 0.1 mm respectively.
What problem does this paper attempt to address?