An experimental investigation of cross flow heat transfer and fluid flow of air over a longitudinally finned flat tubes bank
Ahmed H. Ahmed Maki H. Zaidan Manar S.M. AL-Jethelah a College of Eng,Tikrit University,Iraq,Tikritb Hawija Technical Institute,Renewable Energy Research Unit,Northern Technical University,Iraq,MosulAhmed Hassan Ahmed is currently a Professor at Northern Technical University,Hawija Technical Institute,Renewable Energy Research Unit,holds a MSc degree in mechanical engineering with a specialization in power in 2001 from Tikrit University. He has many researches in heat transfer,renewable energies,power plants,and biofuels.Maki H. Zaidan is currently a Professor at Mechanical Engineering Department,College of Engineering,Tikrit University- Iraq. He received his BSC from Baghdad University- Iraq,MSc from Tikrit University- Iraq,and PhD degree from University of Technology- Iraq. He published a number of papers in prestigious journals and conferences. His areas of interest are thermal solar energy,thermal storage,air-conditioning,nanofluids,phase change materials.Manar S.M Al-Jethelah is currently an Assistant Professor at Mechanical Engineering Department,College of Engineering,Tikrit University- Iraq. She received her BSC and MSc from Tikrit University- Iraq and her PhD degree from University of Guelph- Canada. She published a number of papers in prestigious journals and conferences. Her areas of interest are thermal solar energy,thermal storage,nanofluids,and phase change materials.
DOI: https://doi.org/10.1080/15567036.2024.2390104
2024-08-21
Energy Sources Part A Recovery Utilization and Environmental Effects
Abstract:This paper experimentally investigates the effect of transverse pitch on the heat transfer and fluid flow performance of the longitudinally finned flat tubes (LFFT) bank with staggered configurations. The studied Reynolds number (Re) was based on the hydraulic diameter of the flattened tube with a range of 223≤Re≤1114 . The tubes surfaces were maintained at constant temperature. Three dimensionless transverse pitches ( STˆ ) of LFFT were investigated, i.e. 3.0, 4.0, and 5.0, for dimensionless longitudinal pitch (SLˆ ) = 4.0, dimensionless upstream fin length ( Lu)ˆ = 0.8, dimensionless downstream fin length Ldˆ = 0.8, and dimensionless fin angle ( θˆ) = 0.52, i.e. θ = 30°. The results showed that increasing STˆ from 3 to 5 slightly increased Nu at low Re, i.e. by 1.2% at Re = 223, At higher Re, i.e. 1114, Nu decreased by 20.8% for the same STˆ increase. Be decreased with increasing STˆ up to 60.7% at Re = 223. The thermal-hydraulic performance increased up to 153% at Re = 223.
energy & fuels,engineering, chemical