Ultrasonic thermometric measurement system for solid rocket combustion chambers

Yanlong Wei,Haijian Liang,Gao Wang,Wang Xingqi,Lu Yang,Hanchang Zhou,Luxia Yang,Xiaofang Mu,Guimei Yin
DOI: https://doi.org/10.1016/j.ultras.2021.106361
IF: 4.2
2021-05-01
Ultrasonics
Abstract:<p>Solid rocket motor (SRM) temperature is an important physical parameter for which there is no reliable <em>in situ</em> measurement device, apart from a thermocouple, for such a high temperature environment apart. In this study, an ultrasonic temperature measurement system was designed with an iridium-rhodium-40% alloy waveguide. Laboratory experiments showed that the device obtained ultrasonic signals up to 1800℃ with a temperature fitting curve from room temperature to 1800℃. The thermometer also operated stably under high temperature and produced a repeatable calibration curve, at 97% repeatability. An error band was obtained with 95% confidence. At temperatures above 1000℃, sensitivity gradually increased to a maximum of 0.0035 µs/℃. A corresponding application structure was established for an SRM before subjecting the sensor to a temperature test experiment. The temperature-time curve obtained detected a peak temperature at 1744℃.</p>
acoustics,radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?