Verification of a method using magnetic bead enrichment and nucleic acid extraction to improve the molecular detection of bacterial contamination in blood components

Byungjoon Na,Jinyeop Lee,Ho Eun Chang,Eunseon Park,Sojin Park,Jiyoung Lee,Sujin Oh,Dong Woo Shin,Yun Ji Hong,Kyoung Un Park
DOI: https://doi.org/10.1128/spectrum.02760-23
IF: 3.7
2024-02-06
Microbiology Spectrum
Abstract:The study presents a break through approach to detect bacterial contamination in plasma, a critical concern in transfusion medicine. Traditional methods, such as blood cultures and lateral flow assays, are hampered by slow detection times, low sensitivity, and the need for large blood sample volumes. Our research introduces a novel technique using antibiotic-conjugated magnetic nanobeads combined with real-time PCR, enhancing the detection of bacteria in blood products, especially platelets. This method has shown exceptional efficiency in identifying even low levels of four different species of bacteria in plasma. The ability to detect bacterial contamination rapidly and accurately is vital for ensuring the safety of blood transfusions and can significantly reduce the risk of infections transmitted through blood products. This advancement is a pivotal step in improving patient outcomes and elevating the standards of care in transfusion medicine.
microbiology
What problem does this paper attempt to address?
The paper attempts to address the issue of detecting bacterial contamination in blood products. Specifically, platelets are particularly susceptible to bacterial growth due to the need to store them at room temperature and continuously agitate them for more than 5 days. Traditional bacterial detection methods, such as blood culture and lateral flow chromatography tests, have limitations including long detection times, low sensitivity, and the requirement for large amounts of blood components. Therefore, this study aims to evaluate a technique using antibiotic-conjugated magnetic nanobeads (AcMNBs) for bacterial enrichment, combined with real-time polymerase chain reaction (PCR), to enhance the ability to detect bacterial contamination in plasma. The study experimentally verified that AcMNBs can efficiently capture four types of bacteria, including Staphylococcus aureus, Bacillus cereus, Escherichia coli, and Klebsiella pneumoniae, especially at low concentrations. The results showed that after 24 hours of incubation, the method using AcMNBs and PCR demonstrated significant advantages in detecting these bacteria. Even without incubation, the method effectively improved detection efficiency. This indicates that the method is of great significance for ensuring the safety of blood transfusions and reducing the risk of infections caused by contaminated blood products.