Failure analysis of a forming assembly used in aluminum packaging tubes production

D.G. Papageorgiou,F. Popa,C. Medrea
DOI: https://doi.org/10.1016/j.engfailanal.2024.108452
IF: 4
2024-05-27
Engineering Failure Analysis
Abstract:A local company produces aluminum collapsible tubes for the packaging of a medicinal ointment. A tooling subassembly comprised of a plug and a sleeve is used for the forming of its metallic neck is failing repeatably; it causes extended downtimes to the production line. Historical data was collected, and macroscopic examination was performed. A photographic archive was created so the substantial features of the incident to be recorded. Hardness measurements were carried out on specific surfaces of the parts and the steel grades selected for their manufacturing were identified by chemical analysis. Samples were designated and prepared for optical and electron microscopy. The study involved the examination of the microstructure and fracture morphologies of the specimens derived from the failed parts. Conclusions related to the fracture mechanism and failure mode are presented. Relatively wide dimensional tolerances between the forming tools led to lack of concentricity between the plug and the sleeve provoking malfunction of the forming process and finally lead to the brittle fracture of the die. Furthermore, the frequency of the plug failure should have been an indication of unsuitable material-working hardness combination. Corrective as well as preventive actions are proposed.
engineering, mechanical,materials science, characterization & testing
What problem does this paper attempt to address?