Radionuclides in the Cooling Water Systems for the NuMi Beamline and the Antiproton Production Target Station at Fermilab

Hiroshi Matsumura,Akihiro Toyoda,Kotaro Bessho,Shun Sekimoto,Hiroshi Yashima,Yoshimi Kasugai,Norihiro Matsuda,Yukio Sakamoto,Hiroshi Nakashima,Koji Oishi,David Boehnlein,Gary Lauten,Anthony Leveling,Nikolai Mokhov,Kamran Vaziri
DOI: https://doi.org/10.48550/arXiv.1409.0047
2014-08-29
Accelerator Physics
Abstract:At the 120-GeV proton accelerator facilities of Fermilab, USA, water samples were collected from the cooling water systems for the target, magnetic horn1, magnetic horn2, decay pipe, and hadron absorber at the NuMI beamline as well as from the cooling water systems for the collection lens, pulse magnet and collimator, and beam absorber at the antiproton production target station, just after the shutdown of the accelerators for a maintenance period. Specific activities of {\gamma} -emitting radionuclides and 3H in these samples were determined using high-purity germanium detectors and a liquid scintillation counter. The cooling water contained various radionuclides depending on both major and minor materials in contact with the water. The activity of the radionuclides depended on the presence of a deionizer. Specific activities of 3H were used to estimate the residual rates of 7Be. The estimated residual rates of 7Be in the cooling water were approximately 5% for systems without deionizers and less than 0.1% for systems with deionizers, although the deionizers function to remove 7Be from the cooling water.