A numerical study of the thermal and hydraulic parameters of a finned tube heat exchanger using shear-thinning fluid and rectangular winglet

Dheeraj Kumar,Amaresh Dalal
DOI: https://doi.org/10.1016/j.ijthermalsci.2023.108653
IF: 4.779
2023-09-20
International Journal of Thermal Sciences
Abstract:The flow behavior of non-Newtonian fluid and its effects on the thermohydraulic performance of fin-tube heat exchangers (FTHE) equipped with rectangular winglet pairs have been numerically investigated. Three-dimensional numerical simulations were carried out for a range of Reynolds numbers (50-200) using an aqueous solution of carboxymethylcellulose commonly known as non-Newtonian shear-thinning fluid as a working fluid. These winglets are arranged in a common flow-up and common flow-down configuration and mounted at various angles of attack. The present study examines the effect of attack angle, the orientation of the tubes, the shear-thinning behavior of the carboxymethylcellulose, and the Reynolds numbers on the thermohydraulic performance of the FTHE. The findings reveal that a decrease in the angle of attack up to a certain limit improves thermohydraulic performance by providing better fluid intermixing at the cost of a considerable pressure drop. With an increase in Reynolds numbers, the performance of the FTHE increases by enhancing the Nusslet number of fluid. Additionally, employing aqueous solutions of carboxymethylcellulose as a working fluid in the channel with winglet improves the average Nusselt number and the average quality factor by 124%–186% and 111%–133% respectively compared to the water.
engineering, mechanical,thermodynamics
What problem does this paper attempt to address?