A Fast Evaluation Method for Spatial Point Measurement Accuracy in a Large-Scale Measurement System

Yusong Liu,Wenbo Guo,Yuanyuan Pang,Bo Zheng
DOI: https://doi.org/10.3390/electronics13132428
IF: 2.9
2024-06-22
Electronics
Abstract:In the application domain of large-scale high-precision measurement systems, accurately calibrating the precision of point position measurements is a pivotal issue. Traditional calibration methods rely on laser interferometers and high-precision displacement stages, which are not only costly but also challenging to implement in fixed measurement systems. Addressing this challenge, this study introduces an evaluation method for the spatial point measurement accuracy in large-scale fixed high-precision measurement systems. The models for the relationship between the limit deviation and the maximum deviation of finite measurements were established, as well as the limit deviation and point position measurement accuracy. The spatial point position accuracy of the measurement field was calculated by the measurement errors of a calibration rod. The algorithm was validated using a large-scale measurement platform based on photogrammetric technology. Experimental results demonstrate that the method achieved a point position measurement accuracy calibration better than 0.1 mm within a 20 m measurement range, effectively enhancing the measurement data's accuracy and reliability. This research optimizes the calibration process for large-scale fixed measurement systems, improves calibration efficiency, and obviates the need for complex equipment to complete the calibration process, which is of considerable importance to the development of high-precision spatial point position measurement technology.
engineering, electrical & electronic,computer science, information systems,physics, applied
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to quickly and efficiently evaluate the accuracy of spatial point position measurement in large - scale fixed high - precision measurement systems. Traditional methods rely on laser interferometers and high - precision displacement stages. These devices are not only costly but also pose challenges in implementation within fixed measurement systems. Therefore, this paper proposes a new evaluation method, which calculates the measurement accuracy of spatial point positions in reverse through the errors of a limited number of calibration rod measurements. This method only relies on the calibration rod to complete the accuracy calibration of point position measurement, simplifies the traditional large - scale calibration process, and avoids the need to use laser interferometers and other high - precision displacement platforms. Experimental results show that this method achieves a point - position measurement accuracy calibration better than 0.1 mm within a measurement range of 20 meters, effectively improving the accuracy and reliability of measurement data. Specifically, the following key points are proposed in the paper: 1. **Problem Background**: - The demand for large - scale high - precision measurement systems in the production of high - performance and high - efficiency devices is increasing day by day. - Rapid on - site accuracy verification and calibration remain a common problem faced by manufacturing enterprises when applying high - precision measurement technologies efficiently. 2. **Research Objectives**: - Propose a method for evaluating the measurement accuracy of spatial point positions applicable to large - scale fixed high - precision measurement systems. - Calculate the measurement accuracy of spatial point positions in reverse through the errors of a limited number of calibration rod measurements. 3. **Method Overview**: - Establish a relationship model between the limit deviation and the maximum deviation of a limited number of measurements. - Establish a relationship model between the limit deviation and the point - position measurement accuracy. - Calculate the spatial point - position accuracy of the measurement field through the measurement error of the calibration rod. 4. **Experimental Verification**: - Conduct experimental verification using a large - scale measurement platform based on photogrammetry technology. - Experimental results show that this method achieves a point - position measurement accuracy calibration better than 0.1 mm within a measurement range of 20 meters. Through these studies, the paper optimizes the calibration process of large - scale fixed measurement systems, improves the calibration efficiency, and eliminates the need for complex devices, which is of great significance for the development of high - precision spatial point - position measurement technology.