Cellulose Fiber-Derived Carbon Fiber Networks for Durable Piezoresistive Pressure Sensing

Chenglong Li,Gang Li,Guodong Li,Dehai Yu,Zhaoping Song,Xiaona Liu,Huili Wang,Wenxia Liu
DOI: https://doi.org/10.1021/acsaelm.1c00286
IF: 4.494
2021-05-13
ACS Applied Electronic Materials
Abstract:It is still a large challenge to prepare compressible carbon aerogels for flexible pressure sensors from cellulose-based materials in a green and cost-effective way. Herein we demonstrate a facile strategy to fabricate a compressible carbonized cellulose fiber network (CCFN) strengthened with in situ-synthesized polydopamine (PDA), i.e., PDA–CCFN, for use as flexible pressure sensors. This strategy involves the introduction of aldehyde groups on cellulose fibers and the in situ loading of PDA on the CCFN, which improves the compressibility of the CCFN and endows the PDA–CCFN-based pressure sensor with excellent mechanical durability. The PDA–CCFN-based pressure sensor shows high sensitivity, a low detection limit, a quick response time for loading and unloading, and excellent reproducibility. It has potential applications in monitoring human activities and in wearable biosensing for healthcare. In addition, a 5 × 5 sensor array is prepared and applied for detecting spatially resolved pressures and mapping pressure distribution.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsaelm.1c00286?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsaelm.1c00286</a>.FTIR spectra and gelling process of pristine and periodate-oxidized cellulose fibers; photograph of cellulose fiber network; XRD patterns and FTIR spectra of the CCFN and PDA–CCFN; illustration for change in size of periodate-oxidized cellulose fiber networks before and after carbonization; photographs of the CCFN derived from pristine cellulose fiber, the CCFN derived from periodate-oxidized cellulose fibers, and the PDA–CCFN before and after repeated compression for 1000 cycles; compressive stress-strain curves of CCFN and PDA-CCFN; bending of the PDA–CCFN; original data for sensitivity calculation from a current–time curve under different pressures; durability of the CCFN-based pressure sensor tested by repeatedly loading and unloading a pressure of 20 kPa for 1000 cycles (<a class="ext-link" href="/doi/suppl/10.1021/acsaelm.1c00286/suppl_file/el1c00286_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,engineering, electrical & electronic
What problem does this paper attempt to address?