Development and Validation of a Nomogram for Predicting Non-Adherence to Continuous Positive Airway Pressure Therapy in Patients with Obstructive Sleep Apnea
Xingjia Hu,Yating You,Hui Wang,Yiqing Zheng,Ying Wang
DOI: https://doi.org/10.2147/nss.s488208
2024-10-28
Nature and Science of Sleep
Abstract:Xingjia Hu, 1, 2, &ast Yating You, 2, &ast Hui Wang, 2 Yiqing Zheng, 1, 3 Ying Wang 2 1 The First Affiliated Hospital of Jinan University, Guangzhou, People's Republic of China; 2 Department of Otolaryngology Head and Neck Surgery, Changde Hospital, Xiangya School of Medicine, Central South University, Changde, People's Republic of China; 3 Department of Otolaryngology-HNS, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, People's Republic of China &astThese authors contributed equally to this work Correspondence: Yiqing Zheng, Department of Otolaryngology-HNS, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, 107 Yanjiang west Road, Guangzhou, 510120, People's Republic of China, Email Ying Wang, Department of Otolaryngology Head and Neck Surgery, Changde Hospital, Xiangya School of Medicine, Central South University, No. 818 Renmin Road, Changde, 415000, People's Republic of China, Tel/Fax +86-0731-7788212, Email Background: Continuous positive airway pressure (CPAP) is an effective treatment for obstructive sleep apnea (OSA), but its long-term efficacy is limited by poor patient adherence. This study aimed to develop and validate a predictive nomogram for CPAP non-adherence in patients with OSA. Methods: This is a secondary analysis of a retrospective study. A cohort of 695 Danish patients with OSA were followed for 3 years after initiating CPAP therapy. Independently associated factors were evaluated using multivariate Cox regression, and then nomogram predicting adherence to CPAP use were constructed. The discrimination of the nomogram was assessed using receiver operating characteristic (ROC) curves, calibration curves and decision curve analysis (DCA). Results: Pulmonary disease, oxygen desaturation index (ODI), Epworth Sleepiness Score (ESS) and severity of OSA were identified as predictors and incorporated into the nomogram. The nomogram demonstrated good discrimination with concordance index in training dataset (0.73, 95% CI: 0.69– 0.78) and validation dataset (0.72, 95% CI: 0.66– 0.79). ROC curve, calibration curve, and DCA indicated the nomogram had good clinical utility. Conclusion: This study provided an effective nomogram for predicting CPAP non-adherence in OSA patients. Keywords: continuous positive airway pressure, obstructive sleep apnea, nomogram, patient adherence, predictive model Obstructive sleep apnea (OSA) is a common sleep-related breathing disorder characterized by recurrent episodes of upper airway collapse during sleep, leading to complete or partial cessation of breathing ie hypoxaemia. 1 The characteristic symptoms of OSA include snoring, nocturnal breathing disturbances, and daytime somnolence. Long-term OSA has been associated with various adverse health outcomes, such as hypertension, cardiovascular disease, diabetes, and cognitive impairment, and may even contribute to sudden nocturnal death in severe cases. 2,3 Continuous positive airway pressure (CPAP) therapy is the first-line treatment for OSA. CPAP utilizes a device to provide a constant flow of pressurized air through the nose or mouth, maintaining the patency of the upper airway and preventing apnea or hypoxemia. 4 However, despite the demonstrated efficacy of CPAP, many patients exhibit poor adherence to this treatment, which can compromise treatment outcomes and negatively impact the patient's quality of life. 5 Therefore, identifying the factors that influence CPAP adherence and implementing personalized interventions are crucial for improving CPAP adherence, enhancing the quality of life, and improving the long-term prognosis of patients with OSA. This study aims to develop and validate a predictive modeling framework to estimate the probability of non-adherence to CPAP use within 1–3 years in patients with OSA. This model aspires to identify individuals at high risk of poor adherence before the initiation of treatment, enabling targeted interventions to maximize the likelihood of successful treatment. This was a secondary analysis of a large-scale retrospective observational study. 6 Data were obtained freely from the DATADRYAD database (available at www.datadryad.org ). A total of 695 patients with OSA were consecutively collected at Silkeborg Hospital in Denmark from the 1st of January 2012 to the 28th of February 2013. The research mentioned that the Philips SystemOne REMstar autoCPAP and the ResMed S9 Autoset CPAP were used for patient treatment. Sleep disorder specialist nurses periodically adjust the CPAP settings, mask type, and humidification for all patients until they can tolerate the therapy well. -Abstract Truncated-
neurosciences,clinical neurology