Observation of impurity accumulation and its compatibility with high plasma performance in W7-X
D Zhang,B Buttenschön,S Jablonski,M Kubkowska,O Ford,J A Alcusón,C D Beidler,R Burhenn,M N A Beurskens,A Langenberg,N Pablant,F Reimold,K Rahbarnia,H M Smith,Th Wegner,G Wurden,S A Bozhenkov,Y Feng,K J Brunner,G Fuchert,Y Gao,J Geiger,L Giannone,U Höfel,M Hirsch,Z Huang,J Knauer,T Kremeyer,M Krychowiak,S Kwak,H P Laqua,R Laube,U Neuner,E Pasch,A Pavone,A von Stechow,J Svensson,H Thomsen,the W7-X Team,Daihong Zhang,Birger Buttenschön,Sławomir Jabłoński,Monika Kubkowska,Oliver Ford,Jorge Alberto Alcuson,Craig D Beidler,Rainer Burhenn,Marc N A Beurskens,Andreas Langenberg,Novimir Antoniuk Pablant,Felix Reimold,Kian Rahbarnia,Hakan M Smith,Thomas Wegner,Glen A Wurden,Sergey A Bozhenkov,Yuhe Feng,Kai Jakob Brunner,Golo Fuchert,Yu Gao,Joachim Geiger,Louis Giannone,Udo Höfel,Matthias Hirsch,Jens P Knauer,Thierry Kremeyer,Maciej Krychowiak,Sehyun Kwak,Heinrich Peter Laqua,Ralph Laube,Ulrich Neuner,Ekkehard Pasch,Andrea Pavone,Jakob Svensson
DOI: https://doi.org/10.1088/1361-6587/acf0e7
IF: 2.532
2023-08-18
Plasma Physics and Controlled Fusion
Abstract:At the W7-X stellarator, the bolometer system has measured an intensive radiation zone in the inner plasma region (at a normalized radius ρ~0.3-0.4) in the hydrogen plasma generated by electron cyclotron resonance heating (ECRH); it differs from the normal plasma radiation distribution with an edge-localized emission zone. Spectroscopic diagnostics have recorded high-Z elements such as iron. This phenomenon happens in the plasma phases after the gas supply turn-off, which results in all impurity relevant diagnostic signals increasing for several seconds. Despite the enhancement of the core radiation, the plasma energy confinement is improved. A transport analysis shows that this impurity radiation behavior is associated with a low diffusion coefficient (D ~ 0.02 m 2 /s) and a reversal of the convection around the radial position of the emission peak, which, under normal conditions, separates the zones of outward convection in the central (│V│~ 0.1 m/s) and inward convection in the outer region (│V│~ 0.3 m/s). An impurity accumulation around this radial position has been identified. The transport coefficients obtained are comparable with the theoretical predictions of collisional impurity transport. In the plasma phases studied, both impurity and energy confinement are enhanced. The mechanism responsible for the improvement is believed to be a reduction of micro-instabilities associated with the observed steepening of the density profile, initiated by a low-edge plasma density (< 1.0×1019 m -3 ) after switching off the gas fueling. The normalized temperature and density gradients fulfill the condition for the suppression of ITG turbulence.
physics, fluids & plasmas