Enhanced chromium removal from tannery wastewater through electrocoagulation with iron electrodes: Leveraging the Box-Behnken design for optimization

Edwar Aguilar-Ascón,Liliana Marrufo-Saldaña,Walter Neyra-Ascón
DOI: https://doi.org/10.1016/j.heliyon.2024.e24647
IF: 3.776
2024-01-23
Heliyon
Abstract:This study is focused on reducing total chromium level in tannery wastewater through the electrocoagulation process, in order to comply with the maximum permissible limits (MPL) and to determine the effects from its main operating factors. For this purpose, a batch electrocoagulation reactor was manufactured using iron electrodes. Next, the response surface methodology was applied in the experimental design using a Box-Behnken design (BBD) with three factors: current intensity, treatment time, and pH level. In addition, the total chromium removal percentage was taken as a response variable. The corresponding statistical analysis revealed that the treatment time, current intensity, and pH level variables were significant at a confidence level of P-value<0.05. Obtained in this study for a 99% total chromium removal were: current intensity (I)=2.9A, time (t)=18.1min, and pH=5.6. Our results indicated that the electrocoagulation process effectively removes total chromium from tannery effluents up to MPL values.