X-ray Detectors Based on Ga2O3 Microwires

Chongyang Zhang,Wenjie Dou,Xun Yang,Huaping Zang,Yancheng Chen,Wei Fan,Shaoyi Wang,Weimin Zhou,Xuexia Chen,Chongxin Shan
DOI: https://doi.org/10.3390/ma16134742
2023-06-30
Abstract:X-ray detectors have numerous applications in medical imaging, industrial inspection, and crystal structure analysis. Gallium oxide (Ga2O3) shows potential as a material for high-performance X-ray detectors due to its wide bandgap, relatively high mass attenuation coefficient, and resistance to radiation damage. In this study, we present Sn-doped Ga2O3 microwire detectors for solar-blind and X-ray detection. The developed detectors exhibit a switching ratio of 1.66 × 102 under X-ray irradiation and can operate stably from room temperature to 623 K, which is one of the highest reported operating temperatures for Ga2O3 X-ray detectors to date. These findings offer a promising new direction for the design of Ga2O3-based X-ray detectors.