Sandwich structure magnetometer with a high sensitivity and signal-to-noise ratio based on an ultrahigh-Q CaF2 resonator

Jiamin Bai,Jiamin Rong,Enbo Xing,Ruipu Ji,Jun Yue,Li Li,Wenyao Liu,Yanru Zhou,Jun Tang,Jun Liu
DOI: https://doi.org/10.1364/AO.479580
2023-01-20
Abstract:Whispering gallery mode (WGM) resonators with an ultrahigh quality (Q) factor provide an extremely high resolution for high-precision sensing. However, it is difficult to use them directly in magnetic sensors because of the transparency to the magnetic field. In this paper, a sandwich structure consisting of a neodymium iron boron magnet and calcium fluoride resonator with a Q factor of 109 is proposed. The experimental results show that, compared with the conventional magnetometer, the signal-to-noise ratio of the optical WGM magnetometer reaches 62 dB, with the direct current sensitivity of 42.59 MHz/mT and the AC sensitivity of 794p T H z -1/2 at 42 kHz.
What problem does this paper attempt to address?