Picotesla-sensitivity microcavity optomechanical magnetometry

Zhi-Gang Hu,Yi-Meng Gao,Jian-Fei Liu,Hao Yang,Min Wang,Yuechen Lei,Xin Zhou,Jincheng Li,Xuening Cao,Jinjing Liang,Chao-Qun Hu,Zhilin Li,Yong-Chang Lau,Jian-Wang Cai,Bei-Bei Li
2024-03-21
Abstract:Cavity optomechanical systems have enabled precision sensing of magnetic fields, by leveraging the optical resonance-enhanced readout and mechanical resonance-enhanced response. Previous studies have successfully achieved scalable and reproducible microcavity optomechanical magnetometry (MCOM) by incorporating Terfenol-D thin films into high-quality ($Q$) factor whispering gallery mode (WGM) microcavities. However, the sensitivity was limited to 585 pT/Hz$^{1/2}$, over 20 times inferior to those using Terfenol-D particles. In this work, we propose and demonstrate a high-sensitivity and scalable MCOM approach by sputtering a FeGaB thin film onto a high-$Q$ SiO$_2$ WGM microdisk. Theoretical studies are conducted to explore the magnetic actuation constant and noise-limited sensitivity by varying the parameters of the FeGaB film and SiO$_2$ microdisk. Multiple magnetometers with different radii are fabricated and characterized. By utilizing a microdisk with a radius of 355 $\mu$m and a thickness of 1 $\mu$m, along with a FeGaB film with a radius of 330 $\mu$m and a thickness of 1.3 $\mu$m, we have achieved a remarkable peak sensitivity of 1.68 pT/Hz$^{1/2}$ at 9.52 MHz. This represents a significant improvement of over two orders of magnitude compared with previous studies employing sputtered Terfenol-D film. Notably, the magnetometer operates without a bias magnetic field, thanks to the remarkable soft magnetic properties of the FeGaB film. Furthermore, as a proof-of-concept, we have demonstrated the real-time measurement of a pulsed magnetic field simulating the corona current in a high-voltage transmission line using our developed magnetometer. These high-sensitivity magnetometers hold great potential for various applications, such as magnetic induction tomography and corona current monitoring.
Optics,Applied Physics
What problem does this paper attempt to address?
This paper mainly investigates the sensitivity improvement of Microcavity Optomechanical Magnetometry (MCOM) technology. Traditional MCOM uses Terfenol-D film, but its sensitivity is limited. Researchers propose a new high-sensitivity and scalable MCOM method by sputtering FeGaB film on a high-Q silica microdisk instead of Terfenol-D. Theoretical analysis and experiments show that the peak sensitivity of this improved magnetometer reaches 1.68 pT/Hz^(1/2) at 9.52 MHz, which is two orders of magnitude higher than the previous sputtering Terfenol-D film method. In addition, the newly designed magnetometer does not require a bias magnetic field and can measure the pulsed magnetic field of simulated high-voltage transmission line coronal currents in real-time, due to the excellent soft magnetic properties of FeGaB. These high-sensitivity magnetometers have great potential in applications such as magnetic induction imaging and corona current monitoring.