Bare-Metal Stent Tracking with Magnetic Particle Imaging
Franz Wegner,Thomas Friedrich,Maximilian Wattenberg,Justin Ackers,Malte Sieren,Roman Kloeckner,Joerg Barkhausen,Thorsten Buzug,Matthias Graeser,Anselm von Gladiss
DOI: https://doi.org/10.2147/ijn.s447823
IF: 7.033
2024-03-06
International Journal of Nanomedicine
Abstract:Franz Wegner, 1 Thomas Friedrich, 2 Maximilian Wattenberg, 2 Justin Ackers, 2 Malte Maria Sieren, 1, 3 Roman Kloeckner, 1 Joerg Barkhausen, 3 Thorsten M Buzug, 2, 4 Matthias Graeser, 2, 4 Anselm von Gladiss 5 1 Institute for Interventional Radiology, University of Luebeck, Luebeck, Germany; 2 Fraunhofer Research Institution for Individualized and Cell-Based Medical Engineering IMTE, Luebeck, Germany; 3 Department of Radiology and Nuclear Medicine, University of Luebeck, Luebeck, Germany; 4 Institute of Medical Engineering, University of Lubeck, Luebeck, Germany; 5 Institute for Computer Science, University of Koblenz, Koblenz, Germany Correspondence: Franz Wegner, University of Luebeck, Institute for Interventional Radiology, Ratzeburger Allee 160, Luebeck, 23538, Germany, Tel +4945150072388, Fax +4945150017004, Email Purpose: Magnetic particle imaging (MPI) is an emerging medical imaging modality that is on the verge of clinical use. In recent years, cardiovascular applications have shown huge potential like, e.g., intraprocedural imaging guidance of stent placement through MPI. Due to the lack of signal generation, nano-modifications have been necessary to visualize commercial medical instruments until now. In this work, it is investigated if commercial interventional devices can be tracked with MPI without any nano-modification. Material and Methods: Potential MPI signal generation of nine endovascular metal stents was tested in a commercial MPI scanner. Two of the stents revealed sufficient MPI signal. Because one of the two stents showed relevant heating, the imaging experiments were carried out with a single stent model (Boston Scientific/Wallstent-Uni Endoprothesis, diameter: 16 mm, length: 60 mm). The nitinol stent and its delivery system were investigated in seven different scenarios. Therefore, the samples were placed at 49 defined spatial positions by a robot in a meandering pattern during MPI scans. Image reconstruction was performed, and the mean absolute errors (MAE) between the signals' centers of mass (COM) and ground truth positions were calculated. The stent material was investigated by magnetic particle spectroscopy (MPS) and vibrating sample magnetometry (VSM). To detect metallic components within the delivery system, nondestructive testing via computed tomography was performed. Results: The tracking of the stent and its delivery system was possible without any nano-modification. The MAE of the COM were 1.49 mm for the stent mounted on the delivery system, 3.70 mm for the expanded stent and 1.46 mm for the delivery system without the stent. The results of the MPS and VSM measurements indicate that besides material properties eddy currents seem to be responsible for signal generation. Conclusion: It is possible to image medical instruments with dedicated designs without modifications by means of MPI. This enables a variety of applications without compromising the mechanical and biocompatible properties of the instruments. Keywords: magnetic particle imaging, instrument tracking, interventional instruments, stent, medical imaging Magnetic particle imaging (MPI) is a tracer-based three-dimensional imaging modality. 1 Its intended principle is the visualization of the spatial distribution of superparamagnetic iron-oxide nanoparticles (SPION) due to their non-linear magnetization. The method holds a preclinical status, but first human scale MPI systems have become available. 2–4 Thus, clinical pilot studies seem to be imminent. MPI offers a wide range of potential preclinical and clinical applications. A very promising medical use case of MPI is the guidance of endovascular interventions. Multiple proof-of-concept studies illustrated, e.g., the potential of radiation-free stent implantation, balloon angioplasty and artifact-free stent lumen quantification. 5–7 Especially, the high temporal resolution which allows for real-time imaging 8 renders MPI very advantageous to overcome the harmful characteristic of X-ray-based periprocedural imaging. Because of its tracer-based principle, most medical instruments are invisible in MPI, as they do not generate sufficient MPI signal. 7,9,10 To overcome this limitation, endovascular devices like stents, catheters and guidewires have been modified with dedicated marking technologies to make them visible in MPI. 5,11–13 SPION-coatings as well as polymer-integrated nanoparticles have been introduced as visualization techniques. However, both approaches change the mechanical properties of the devices and require sophisticated production -Abstract Truncated-
pharmacology & pharmacy,nanoscience & nanotechnology