Magnetic Particle Imaging: In vitro Signal Analysis and Lumen Quantification of 21 Endovascular Stents

Franz Wegner,Anselm von Gladiss,Julian Haegele,Ulrike Grzyska,Malte Maria Sieren,Erik Stahlberg,Thekla Helene Oechtering,Kerstin Lüdtke-Buzug,Joerg Barkhausen,Thorsten M Buzug,Thomas Friedrich
DOI: https://doi.org/10.2147/IJN.S284694
IF: 7.033
2021-01-11
International Journal of Nanomedicine
Abstract:Franz Wegner, 1, * Anselm von Gladiss, 2, * Julian Haegele, 1, 3 Ulrike Grzyska, 1 Malte Maria Sieren, 1 Erik Stahlberg, 1 Thekla Helene Oechtering, 1 Kerstin Lüdtke-Buzug, 2 Joerg Barkhausen, 1 Thorsten M Buzug, 2, 4 Thomas Friedrich 2, 4 1 Department of Radiology and Nuclear Medicine, University of Lübeck, Lübeck, Germany; 2 Institute of Medical Engineering, University of Lübeck, Lübeck, Germany; 3 Zentrum für Radiologie und Nuklearmedizin Rheinland, Dormagen, Germany; 4 Fraunhofer Research Institution for Individualized and Cell-Based Medical Engineering, Lübeck, Germany *These authors contributed equally to this work Correspondence: Franz Wegner University Hospital Schleswig-Holstein, Campus Lübeck, Department of Radiology and Nuclear Medicine, Ratzeburger Allee 160, Lübeck 23538, Germany Tel +004945150017001 Fax +004945150017004 Email franz.wegner@uksh.de Purpose: Endovascular stents are medical devices, which are implanted in stenosed blood vessels to ensure sufficient blood flow. Due to a high rate of in-stent re-stenoses, there is the need of a noninvasive imaging method for the early detection of stent occlusion. The evaluation of the stent lumen with computed tomography (CT) and magnetic resonance imaging (MRI) is limited by material-induced artifacts. The purpose of this work is to investigate the potential of the tracer-based modality magnetic particle imaging (MPI) for stent lumen visualization and quantification. Methods: In this in vitro study, 21 endovascular stents were investigated in a preclinical MPI scanner. Therefore, the stents were implanted in vessel phantoms. For the signal analysis, the phantoms were scanned without tracer material, and the signal-to-noise-ratio was analyzed. For the evaluation of potential artifacts and the lumen quantification, the phantoms were filled with diluted tracer agent. To calculate the stent lumen diameter a calibrated threshold value was applied. Results: We can show that it is possible to visualize the lumen of a variety of endovascular stents without material induced artifacts, as the stents do not generate sufficient signals in MPI. The stent lumen quantification showed a direct correlation between the calculated and nominal diameter (r = 0.98). Conclusion: In contrast to MRI and CT, MPI is able to visualize and quantify stent lumina very accurately. Keywords: magnetic particle imaging, endovascular stents, artifacts, superparamagnetic iron oxide nanoparticles, lumen quantification
pharmacology & pharmacy,nanoscience & nanotechnology
What problem does this paper attempt to address?