Higher Dose to Organs at Risk: the Unintended Consequences of Intravenous Contrast Use in Computed Tomography Simulation for Cervical Cancer.
Dunhuang Wang,Bo Yang,Weiping Wang,Xiaoliang Liu,Yongguang Liang,Shuai Sun,Jiabin Ma,Bing Zhou,Ke Hu,Fuquan Zhang
DOI: https://doi.org/10.1016/j.prro.2021.08.002
IF: 3.439
2021-01-01
Practical Radiation Oncology
Abstract:Purpose: To compare the volumes of interest and doses to the organs at risk on contrast and noncontrast scans in patients with cervical cancer who underwent prophylactic extended-field radiation therapy (EFRT). Methods and Materials: We reviewed twenty cervical cancer patients treated with prophylactic EFRT at Peking Union Medical College Hospital between March 2021 and April 2021. Each patient underwent noncontrast and contrast scans during simulation. All structures were contoured, and radiation therapy plans were created based on both scans. Student t test and Pearson correlation coefficient test were performed. Results: Compared with the noncontrast scan, on the contrast scan, the mean volume of the inferior vena cava expanded by 44% (P = .001), and the mean volume of the para-aortic nodal clinical target volume increased by 17% (P = .001). For the second portion of the duodenum, the V30 (38.2% vs 43.8%, P = .038), V35 (27.6% vs 35.1%, P = .002), V40 (18.3% vs 26.3%, P = .014), V45 (11.2% vs 18.5%, P = .008), and V50 (4.2% vs 9.1%, P = .005) were significantly lower on the noncontrast scan than on the contrast scan. For the third portion of the duodenum, the V45 (78.4% vs 81.6%, P = .03) and V50 (59.7% vs 67%, P = .001) were significantly lower on the noncontrast scan than on the contrast scan. For the right kidney, the V5, V10, V15, V20, and V25 on the contrast and noncontrast scans were 85.4% versus 79.8% (P = .013), 52.5% versus 45.6% (P = .021), 25.6% versus 20.1% (P = .003), 11.1% versus 7.5% (P = .001), and 3.8% versus 2.3% (P = .027), respectively. Conclusions: Compared with the noncontrast scan, expansion of the inferior vena cava on the contrast scan can lead to excessive contouring and an overdose to the duodenum and right kidney in cervical cancer patients treated with prophylactic EFRT. (C) 2021 The Authors. Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.