Comment on: Does time of intraoperative exposure to the aerobiome increase microbial growth on inflatable penile prostheses?

John J. Mulcahy
DOI: https://doi.org/10.1038/s41443-024-00907-5
2024-06-01
International Journal of Impotence Research
Abstract:Fortunately, infection associated with a penile prosthesis is rare, but can be a devastating event associated with removal of the device [1]. Studies to elucidate the causes of such an occurrence and methods to prevent it have reduced the incidence [2, 3]. Among patient characteristics, diabetes mellitus and immunosuppression appear to have increased risk of penile prosthesis infection [3]. In relation to the process, primary (initial) surgery and penile prostheses coated with an infection-retardant material seem to reduce the risk of infection [3]. In addition to those risk factors, longer surgeries are assumed to increase the risk of infection because of the increased potential for colonization and the subsequent production of biofilms. However, this theory has never been tested in the field of prosthetic urology. The manuscript of Madhusoodanan et al. [4] demonstrated that swabs for culture from a rear tip extender and reservoir of a Coloplast Titan implant showed no growth of any type of organism when taken at 30-min intervals up to 3 h at ambient operating room conditions. This important information reinforces the fact that efforts to reduce ambient organism exposure in the operation room, such as laminar flow systems and surgical isolation bubbles, which are expensive and cumbersome to use, are unnecessary. Infections associated with urologic prostheses are thought to come from the skin surrounding the incision [5]. In this study, the control group was swab cultures taken from non-prepped scrotal skin obtained from patients about to have a bilateral vasectomy. All such cultures showed microbial growth, most commonly Corynebacterium. This outcome could be expected. A more useful control group or a separate study group might be swab cultures taken at 30-min intervals up to 3 h from prepped scrotal skin adjacent to an incision for penile implant placement, or a scrotal procedure which would be longer lasting. Previous studies have shown that recolonization of skin after surgical prep and incision increases with time [6]. The proposed study might elucidate a timeframe within which a procedure to insert a penile implant should be completed to help minimize the chance of an infection occurring.
urology & nephrology
What problem does this paper attempt to address?