An Optical Signal Simulator for the Characterization of Photoplethysmographic Devices

Erika Pittella,Orlandino Testa,Luca PodestÃ,Emanuele Piuzzi
DOI: https://doi.org/10.3390/s24031008
IF: 3.9
2024-02-05
Sensors
Abstract:(1) Background: An optical simulator able to provide a repeatable signal with desired characteristics as an input to a photoplethysmographic (PPG) device is presented in order to compare the performance of different PPG devices and also to test the devices with PPG signals available in online databases. (2) Methods: The optical simulator consists of an electronic board containing a photodiode and LEDs at different wavelengths in order to simulate light reflected by the body; the PPG signal taken from the chosen database is reproduced by the electronic board, and the board is used to test a wearable PPG medical device in the form of earbuds. (3) Results: The PPG device response to different average and peak-to-peak signal amplitudes is shown in order to assess the device sensitivity, and the fidelity in tracking the actual heart rate is also investigated. (4) Conclusions: The developed optical simulator promises to be an affordable, flexible, and reliable solution to test PPG devices in the lab, allowing the testing of their actual performances thanks to the possibility of using PPG databases, thus gaining useful and significant information before on-the-field clinical trials.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop an optical signal simulator to provide repeatable signals with the required characteristics as the input of Photoplethysmographic (PPG) devices. Specifically, this research aims to improve the testing and characterization of PPG devices in the following ways: 1. **Comparing the performance of different PPG devices**: By using the same standardized signal source, the performance of different PPG devices can be evaluated and compared more accurately. 2. **Testing with PPG signals in the database**: Existing arterial models have limitations in generating arbitrary signals and processing high - heart - rate signals. The new optical simulator can utilize PPG signals from online databases, which are from individuals with different physiological and pathological characteristics, thereby enhancing the authenticity and extensiveness of the tests. 3. **Improving the flexibility and reliability of testing**: The optical simulator can generate highly repeatable and controllable signals, making the test results more reliable and allowing researchers to independently adjust the mean value (DC component) and peak - to - peak amplitude (AC component) of the signals in order to better test the sensitivity of the devices. ### Specific problem description - **Background**: Cardiovascular diseases are a major global public health challenge, and early diagnosis and prevention are crucial. PPG technology, as a non - invasive monitoring method, can detect changes in vascular blood volume and provide important physiological parameters such as heart rate and blood oxygen saturation. - **Existing problems**: Traditional arterial models have deficiencies in signal generation and response speed, which limit their application in high - heart - rate situations. In addition, it is difficult to achieve completely consistent and repeatable conditions when directly contacting the human body for testing. - **Solution**: Develop an optical signal simulator to simulate light reflection through photodiodes on the electronic board and LEDs of different wavelengths to reproduce PPG signals. This allows comprehensive and reliable testing of PPG devices in a laboratory environment without relying on actual human data. ### Summary The main objective of this research is to provide an economical, flexible, and reliable solution for testing and characterizing the performance of PPG devices by developing a new - type optical signal simulator. This not only helps to improve the accuracy and reliability of the devices but also can provide valuable data support for clinical trials.