Photon-counting detector CT – first experiences in the field of musculoskeletal radiology

Stefanie Bette,Franka Risch,Judith Becker,Daniel Popp,Josua A. Decker,David Kaufmann,Lena Friedrich,Christian Scheurig-Münkler,Florian Schwarz,Thomas J Kröncke
DOI: https://doi.org/10.1055/a-2312-6914
2024-05-25
RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Abstract:The introduction of photon-counting detector CT (PCD-CT) marks a remarkable leap in innovation in CT imaging. The new detector technology allows X-rays to be converted directly into an electrical signal without an intermediate step via a scintillation layer and allows the energy of individual photons to be measured. Initial data show high spatial resolution, complete elimination of electronic noise, and steady availability of spectral image data sets. In particular, the new technology shows promise with respect to the imaging of osseous structures. Recently, PCD-CT was implemented in the clinical routine. The aim of this review was to summarize recent studies and to show our first experiences with photon-counting detector technology in the field of musculoskeletal radiology. We performed a literature search using Medline and included a total of 90 articles and reviews that covered recent experimental and clinical experiences with the new technology. In this review, we focus on (1) spatial resolution and delineation of fine anatomic structures, (2) reduction of radiation dose, (3) electronic noise, (4) techniques for metal artifact reduction, and (5) possibilities of spectral imaging. This article provides insight into our first experiences with photon-counting detector technology and shows results and images from experimental and clinical studies.
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?
The paper aims to summarize the latest experimental and clinical experiences of Photon-Counting Detector CT (PCD-CT) in the field of musculoskeletal radiology. Specifically, this review focuses on the following aspects: 1. **Spatial resolution and depiction of fine anatomical structures**: PCD-CT can provide higher spatial resolution, which is crucial for depicting fine details in bone structures. 2. **Radiation dose reduction**: Compared to traditional CT, PCD-CT can obtain high-quality images at a lower radiation dose, which is particularly important for patients who require frequent CT examinations. 3. **Reduction of electronic noise**: By directly converting X-ray photons into electrical signals, PCD-CT eliminates electronic noise, thereby improving image quality. 4. **Metal artifact reduction techniques**: PCD-CT excels in reducing artifacts caused by metal implants, which aids in the interpretation of adjacent structures in postoperative and follow-up imaging. 5. **Possibility of spectral imaging**: PCD-CT can routinely acquire spectral datasets, allowing for material classification, such as detecting uric acid crystals in gout or displaying bone marrow edema. In summary, this review summarizes recent experimental and clinical studies on PCD-CT in the field of musculoskeletal radiology and showcases the preliminary experiences and results of the authors' team with this new technology.