Wind-tunnel measurements and LES simulations of air pollutant dispersion caused by fire-induced buoyancy plume inside two parallel street canyons
Peng-Yi Cui,Jin-Hao Zhang,Yi-Ping Wu,Yan Zhang,Jia-Zheng Zhou,Yang Luo,Yuan-Dong Huang
DOI: https://doi.org/10.1016/j.psep.2020.04.047
IF: 7.8
2020-08-01
Process Safety and Environmental Protection
Abstract:Air pollutant dispersion caused by fire-induced buoyancy plume is studied.FDS with LES was employed to simulate the indoor fires at different floors.Thermal buoyancy effect was considered by burning smoke cake in WT tests.There exist <em>Fr</em><sub>crit,1</sub> = 0.313 and <em>Fr</em><sub>crit,2</sub> = 0.389 to divide dispersion regimes.The formulas between <em>U</em><sub>crit</sub> and <em>Z</em><sub>ref</sub> at different floors were further confirmed.A physical model consisting of two parallel street canyons with the fire room located in the windward side of the first street canyon was established. Large eddy simulation (LES) was employed to investigate the effects of air pollutant dispersion caused by the fire-induced buoyancy plume on the indoor and outdoor air quality. The effect of thermal buoyancy was firstly taken into account by burning the smoke cakes in wind-tunnel experiments under different <em>Fr</em> (Froude number) cases. Results show that the diffusion characteristics of smoke plume, temperature and velocity distributions by wind-tunnel measurements agreed well with the numerical models. According to the smoke soot's effects on two street canyons, the dispersion of fire pollutants can be divided into three regimes. There exist two critical <em>Fr</em>, <em>Fr</em><sub>crit,1</sub> = 0.313 and <em>Fr</em><sub>crit,2</sub> = 0.389, at which the smoke plume begins to influence the 1st and 2nd street canyons, respectively. Moreover, the region areas of <em>w</em> < 0 (vertical velocity) can indirectly represent the concentration distribution of pollutants, and the temperature distribution is closely proportional to the distribution of pollutant (smoke plume, CO<sub>2</sub> and CO) concentration, that is, where the plume concentration is high, the temperature is high. The quantitative formulas between <em>U</em><sub>crit</sub> (<em>U</em><sub>crit,1</sub> and <em>U</em><sub>crit,2</sub>) and the reference height (<em>Z</em><sub>ref</sub>) of the fire source at different floors were further confirmed. This study provides a new idea for visualizing the diffusion characteristics of fire pollutants, and is helpful for dealing with the building fire, personnel evacuation and emergency escape.<span class="display"><span><ol class="links-for-figure"><li><a class="anchor download-link u-font-sans" href="https://ars.els-cdn.com/content/image/1-s2.0-S0957582020306133-fx1_lrg.jpg"><span class="anchor-text">Download : <span class="download-link-title">Download high-res image (173KB)</span></span></a></li><li><a class="anchor download-link u-font-sans" href="https://ars.els-cdn.com/content/image/1-s2.0-S0957582020306133-fx1.jpg"><span class="anchor-text">Download : <span class="download-link-title">Download full-size image</span></span></a></li></ol></span></span>Both FDS model and wind-tunnel experiment show that there exist two critical <em>Fr</em>, <em>Fr</em><sub>crit,1</sub> = 0.313 and <em>Fr</em><sub>crit,2</sub> = 0.389 as demarcation points, at which the smoke plume begins to influence the 1st and 2nd street canyons, respectively.
engineering, environmental, chemical