Wavelet analysis of oximetry recordings to assist in the automated detection of moderate-to-severe pediatric sleep apnea-hypopnea syndrome

Fernando Vaquerizo-Villar,Daniel Álvarez,Leila Kheirandish-Gozal,Gonzalo C Gutiérrez-Tobal,Verónica Barroso-García,Andrea Crespo,Félix Del Campo,David Gozal,Roberto Hornero
DOI: https://doi.org/10.1371/journal.pone.0208502
IF: 3.7
2018-12-07
PLoS ONE
Abstract:Background: The gold standard for pediatric sleep apnea hypopnea syndrome (SAHS) is overnight polysomnography, which has several limitations. Thus, simplified diagnosis techniques become necessary. Objective: The aim of this study is twofold: (i) to analyze the blood oxygen saturation (SpO2) signal from nocturnal oximetry by means of features from the wavelet transform in order to characterize pediatric SAHS; (ii) to evaluate the usefulness of the extracted features to assist in the detection of pediatric SAHS. Methods: 981 SpO2 signals from children ranging 2-13 years of age were used. Discrete wavelet transform (DWT) was employed due to its suitability to deal with non-stationary signals as well as the ability to analyze the SAHS-related low frequency components of the SpO2 signal with high resolution. In addition, 3% oxygen desaturation index (ODI3), statistical moments and power spectral density (PSD) features were computed. Fast correlation-based filter was applied to select a feature subset. This subset fed three classifiers (logistic regression, support vector machines (SVM), and multilayer perceptron) trained to determine the presence of moderate-to-severe pediatric SAHS (apnea-hypopnea index cutoff ≥ 5 events per hour). Results: The wavelet entropy and features computed in the D9 detail level of the DWT reached significant differences associated with the presence of SAHS. All the proposed classifiers fed with a selected feature subset composed of ODI3, statistical moments, PSD, and DWT features outperformed every single feature. SVM reached the highest performance. It achieved 84.0% accuracy (71.9% sensitivity, 91.1% specificity), outperforming state-of-the-art studies in the detection of moderate-to-severe SAHS using the SpO2 signal alone. Conclusion: Wavelet analysis could be a reliable tool to analyze the oximetry signal in order to assist in the automated detection of moderate-to-severe pediatric SAHS. Hence, pediatric subjects suffering from moderate-to-severe SAHS could benefit from an accurate simplified screening test only using the SpO2 signal.
What problem does this paper attempt to address?