Detection of Sleep Apnea-Hypopnea Events Using Millimeter-wave Radar and Pulse Oximeter

Wei Wang,Chenyang Li,Zhaoxi Chen,Wenyu Zhang,Zetao Wang,Xi Guo,Jian Guan,Gang Li
2024-09-28
Abstract:Obstructive Sleep Apnea-Hypopnea Syndrome (OSAHS) is a sleep-related breathing disorder associated with significant morbidity and mortality worldwide. The gold standard for OSAHS diagnosis, polysomnography (PSG), faces challenges in popularization due to its high cost and complexity. Recently, radar has shown potential in detecting sleep apnea-hypopnea events (SAE) with the advantages of low cost and non-contact monitoring. However, existing studies, especially those using deep learning, employ segment-based classification approach for SAE detection, making the task of event quantity estimation difficult. Additionally, radar-based SAE detection is susceptible to interference from body movements and the environment. Oxygen saturation (SpO2) can offer valuable information about OSAHS, but it also has certain limitations and cannot be used alone for diagnosis. In this study, we propose a method using millimeter-wave radar and pulse oximeter to detect SAE, called ROSA. It fuses information from both sensors, and directly predicts the temporal localization of SAE. Experimental results demonstrate a high degree of consistency (ICC=0.9864) between AHI from ROSA and PSG. This study presents an effective method with low-load device for the diagnosis of OSAHS.
Signal Processing
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the detection of obstructive sleep apnea - hypopnea syndrome (OSAHS). OSAHS is a sleep - related breathing disorder associated with significant morbidity and mortality. Currently, the gold - standard method for diagnosing OSAHS is polysomnography (PSG), but it faces challenges in popular application due to its high cost and complexity. Although radar technology has shown potential in non - contact monitoring of sleep apnea - hypopnea events (SAE), existing research, especially methods using deep learning, usually adopt a fragment - based classification method to detect SAE, which makes it difficult to estimate the number of events. In addition, radar detection of SAE is easily affected by body movement and environmental interference. Although oxygen saturation (SpO₂) can provide valuable information about OSAHS, it also has certain limitations and cannot be used alone for diagnosis. To overcome these challenges, this paper proposes a method that combines millimeter - wave radar and pulse oximeter, called ROSA, to directly predict the time location of SAE. This method fuses the information of the two sensors and shows a high consistency (ICC = 0.9864) between ROSA and PSG in AHI (apnea - hypopnea index, the number of apnea - hypopnea events per hour of sleep) through experimental results. This indicates that ROSA provides an effective and low - cost device for the diagnosis of OSAHS.