Stability Valorization of Hydrofluoroolefine HFO-1336mzzE and Its Mixtures under Arc Discharge Conditions

Elisabeth Bilbao,Xinyi Xia,María Luz Alonso,Rosa María Alonso,Jesús Izcara,Josu Izagirre,José Ignacio Lombraña,María Luz Alonso,Rosa María Alonso,Jesús Izcara,José Ignacio Lombraña
DOI: https://doi.org/10.1021/acs.iecr.3c03835
2024-02-12
Industrial & Engineering Chemistry Research
Abstract:Sulfur hexafluoride (SF6) has been conventionally used as an insulating gas in switchgear. However, owing to its high Global-warming Potential (GWP), the United Nations Framework Convention on Climate Change (UNFCCC) calls for its replacement with alternative gases. In this work, hydrofluoroolefine HFO-1336mzzE is analyzed as an alternative, due to its good dielectric strength and low GWP. For this purpose, the influence of electric discharges on the stability of this gas in mixtures with vector gases (air, CO2 and N2) at 20% (v/v) was studied, and the influence of humidity (0, 200, and 500 ppm) and temperature (25 °C, 60 and 120 °C) was determined. Electric arc discharge was conducted by a gas-insulated medium voltage switchgear prototype specifically designed for this work. Its main characteristic is the uniform distribution of the dissipated energy, facilitating better reproducibility of the results. The degradation of HFO-1336mzzE was monitored by gas chromatography coupled to mass spectrometry (GC/MS) sampling in addition to online measurement using Near-infrared spectroscopy (NIR). The degradation rate (DR) was measured by assessing the concentrations of the different degradation gases occurring in each experiment. The results were evaluated by using density functional theory (DFT) and transition state theory (TS). Finally, the DR analysis was completed with a study of coke formation for prolonged discharge periods. The gas mixture containing CO2 showed a higher stability compared to those containing air or N2, with temperature being the most decisive factor. A declining trend in the degradation rate tending toward stabilization was observed, rendering CO2 the preferred carrier gas.
engineering, chemical
What problem does this paper attempt to address?
### Problems Addressed by the Paper This paper aims to study the stability of hydrofluoroolefin HFO-1336mzzE (referred to as HFO4E) in mixed gases under different operating conditions such as humidity, temperature, and arc discharge. Specifically, the paper addresses the following issues: 1. **Replacement of SF6**: - SF6 is a widely used insulating gas, but due to its high global warming potential (GWP), alternatives need to be found. HFO4E has been selected as a potential replacement due to its good dielectric strength and low GWP. 2. **Selection of Mixed Gases**: - The stability of HFO4E mixed with different carrier gases (air, CO2, and N2) was studied. The proportions of these mixtures were 20% v/v HFO4E and 80% v/v carrier gas. 3. **Analysis of Influencing Factors**: - The effects of humidity (0, 200, and 500 ppm) and temperature (25°C, 60°C, and 120°C) on the stability of HFO4E were analyzed. 4. **Experimental Design and Methods**: - A specially designed gas-insulated switchgear prototype was used for arc discharge experiments. The degradation of HFO4E was monitored using gas chromatography-mass spectrometry (GC/MS) and near-infrared spectroscopy (NIR) techniques. 5. **Results Analysis**: - The degradation rate (DR) was evaluated using density functional theory (DFT) and transition state theory (TS). The study found that under arc discharge conditions, HFO4E had the highest stability when CO2 was used as the carrier gas. In summary, this paper aims to explore the stability and degradation behavior of HFO4E as a potential SF6 replacement under different conditions and to verify its feasibility through experiments.