Abstract:With the rapid development of atom interference technology, multi-loop atom interferometers are widely used in the high-precision measurement of various physical constants and testing of various gravity-related effects. However, in ground-based multi-loop atom interference experiments, the systematic error contribution by classical effects is an important factor that affects the experimental measurement accuracy and gravitational effect detection. Based on this, we used the atomic wave-function evolution-phase accumulation method to provide a high-order interference phase of multi-loop atom interferometers in an inhomogeneous gravitational field containing Earth's rotation. Furthermore, we propose a new scheme that combines optimised frequency-shift compensation technology with an improved pulse sequence to eliminate systematic errors due to the gravity gradient, Earth's rotation, and their coupling effect with the pulse duration, as well as the coupling effect of laser detuning with the pulse duration. This study lays a theoretical foundation for experiments on multi-loop atom interferometers with higher precision.