Improvement of the Measuring Precision by Changing the Pulse Sequence in the Three-Level Atom Gravimeter

SL Zheng,J Chen,Q Lin
DOI: https://doi.org/10.7498/aps.54.3535
IF: 0.906
2005-01-01
Acta Physica Sinica
Abstract:We introduced a method that can improve the measurement precision of the three-level atom gravimeter by changing the sequence of the pulses. A 3×3 matrix is put forward to describe the propagation of atomic beams, the interaction between the three-level atoms and bichromatic laser fields, and to calculate the phase difference of the atom interferometers. We obtained also the relation between g ravity and the phase difference of the atom gravimeter. It is found that the pre cision of the three-level atom gravimeter can be increased simply by change the sequence of the optical pulses.
What problem does this paper attempt to address?