Evaluation Of Elastomer For Use In Facial Prostheses After Exposure To Skin Secretions, Sunscreen And Disinfectant Agent.

Maria Eduarda Broering da SILVA,Laura Cristina Silveira QUADROS,Cláudia Helena SILVA-LOVATO,Artur Ferronato SOTO,Juliana Silva RIBEIRO de ANDRADE,Thaís Mageste DUQUE,Maurício Malheiro BADARÓ
DOI: https://doi.org/10.1016/j.oooo.2023.12.692
2024-06-07
Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
Abstract:Objective. This study evaluates the influence of sweat, sebum, sunscreen, and disinfectant on the color stability and hardness of elastomers for facial prostheses. Study Design. Intrinsically pigmented specimens remained in contact with human skin for 30 days, considering exposures (n=36/group), absent (Control, C); sweat and oiliness (SO); sweat and oiliness associated with sunscreen (SOS); 0.12% chlorhexidine digluconate (CD0.12%); all agents (SOSCD). The variables were color change (CIELab and NBS) and shore A hardness measured at baseline and 30 days.