Evaluation of the permanence of benzene on solid material with GC–MS analytical techniques, at time intervals

Claudio De Maio
DOI: https://doi.org/10.1140/epjp/s13360-024-05410-w
2024-07-20
The European Physical Journal Plus
Abstract:The aim of the work is to evaluate the permanence of flame accelerators (pure benzene) in a solid matrix, at regular intervals of time, in order to create a procedure that gives indications on the time within which the fire investigation teams can detect the presence of flame accelerants and its decay, if exposed to air. 1μl of benzene was placed on a 1cm x 1cm piece of cotton cloth, and tested for the presence of benzene after 0–6-12–24-36–48-72–120-240–360 h. The analytical technique used to give answers to this is the use of the gas chromatograph—mass spectrometer (GC–MS), which allows to detect the presence of flame accelerators even in small quantities in the samples. A series of a variety of benzene-soaked samples will be reproduced in a controlled environment, originally containing flame-accelerating materials, and then compared to each other to evaluate a benzene dispersion curve on the samples. The results will be obtained by GC–MS analysis with helium carrier gas and ASTM A1618 method, in order to give an indication of how long it is still possible to find traces of pure flame accelerators on solid matrices. This work also aims to lay the foundations for subsequent experiments with other commonly used materials.
physics, multidisciplinary
What problem does this paper attempt to address?