Determination of bismuth ion in biological and water samples with a potentiometric sensor using carbon paste electrode as a straightforward and simple indicator electrode
Mahnaz Sanati,Mahboubeh Masrournia,Hossein Behmadi,Ali Beyramabadi
DOI: https://doi.org/10.1007/s13738-022-02526-7
2022-03-08
Journal of the Iranian Chemical Society
Abstract:Bismuth and its derivatives are important compounds that are used in various industries in alloy, laser, and semiconductor preparations, energy storage applications, thermoelectric applications, and pharmacological applications. In the study, a potentiometric sensor was prepared to measure Bi(III) ions in the real water and pharmacological samples using a carbon paste electrode (CPE) as an indicator electrode. Several components were chosen to prepare the best CPE, including graphite powder, a binder, carbon-based nanomaterials as a modifier agent, and an ionophore (synthetic Schiff base). For the selected best CPE composite, effects of three synthetic Schiff bases as the CPE ionophore, two binders (paraffin oil and an ionic liquid ([Bmim][BF4])), and four carbon-based nanomaterials (graphene, multi-walled carbon nanotubes, amino-functionalized MWCNTs, and carboxyl-functionalized MWCNTs) were compared in the Bi(III) ion determination. Four CPE components, including graphite powder, ionic liquid ([Bmim][BF4]), graphene, and a synthetic Schiff base were selected as the best CPE composite and their percentages were optimized using an experimental design. For this purpose, an optimal mixture design consisting of 20 runs was created to optimize the percentage of CPE components. Under the optimum percentage of CPE composite, the sensor displayed linearity in the range of 4.8 × 10–7–1.0 × 10–2 M, a slope of 19.17 ± 0.57 mV decade−1, a limit of detection of 1.45 × 10–7 M, a response time of 5 s, and a lifetime of 9 weeks to measure Bi(III) ions. The sensor selectivity was investigated based on the matched potential method (MPM), indicating the sensor has high selectivity toward Bi(III) ions in the presence of various interfering species. The application of the sensor to determine Bi(III) ions was evaluated by analyzing several real samples such as well water samples, river water samples, and pharmacological products. The relative recoveries for the real samples were in the range of 93.8–98.1% with a relative standard deviation between 0.71 and 1.98%, indicating that the sensor has an excellent ability to the routine measurement of Bi(III) ion in the pharmacological and water samples with a suitable linear range and fast response time.
chemistry, multidisciplinary