Hemodynamic evaluation in preterm infants using ultrasonic cardiac output monitor (USCOM)

Daniela Doni,Martha Caterina Faraguna,Emanuela Zannin,Alessandro Rinaldi,Claudia Cafolla,Lucia Iozzi,Valeria Cavalleri,Camilla Rigotti,Mariateresa Sinelli,Tiziana Fedeli,Maria Luisa Ventura
DOI: https://doi.org/10.1007/s00431-024-05465-y
2024-02-21
European Journal of Pediatrics
Abstract:We aimed to establish reference ranges for USCOM parameters in preterm infants, determine factors that affect cardiac output, and evaluate the measurement repeatability. This retro-prospective study was performed at Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy. We included infants below 32 weeks of gestational age (GA) and/or 1500 g of birth weight (BW). We excluded infants with congenital heart diseases or hemodynamic instability. Measurements were performed at 3 ± 1, 7 ± 2, and 14 ± 2 postnatal days. We analyzed 204 measurements from 92 patients (median GA = 30.57 weeks, BW = 1360 g). The mean (SD) cardiac output (CO) was 278 (55) ml/min/kg, cardiac index (CI) was 3.1 (0.5) L/min/m 2 , and systemic vascular resistance (SVRI) was 1292 (294) d*s*cm −5 /m 2 . CO presented a negative correlation with postmenstrual age (PMA), while SVRI presented a positive correlation with PMA. The repeatability coefficient was 31 ml/kg/min (12%).
pediatrics
What problem does this paper attempt to address?